Potential for cavitation, leading to partial discharge, hot spots, and thermal cycling cracks
Service life may be reduced by 40–60%
Evacuates air at ≤5 mbar
Injects UL94V-0 epoxy resin and cures in a moisture-free environment
Significantly improves insulation performance and thermal stability
A vacuum-potted medical device transformer passed a 50,000-hour accelerated aging test.
A non-vacuum-potted device failed after 18,000 hours.
| Stressor | Consequence | Vacuum Molded Benefit |
|---|---|---|
| Vibration (5–2000Hz) | Wire fatigue | Dampens resonance 300% better |
| Thermal shock (-40~125°C) | Solder joint cracks | CTE-matched resin absorption |
| Humidity (85% RH) | Corrosion tracking | Zero permeability barrier |
–Don’t rely solely on the datasheet, request:
–X-ray scan showing void distribution
–Cross-section report measuring bubble size
–Thermal shock test (-55°C to +150°C, 500 cycles)
–Partial discharge test <5 pC (at 2x the operating voltage)
YHDC’s PCB transformers utilize vacuum forming technology, resulting in extremely high voltage withstand performance, enhanced resistance to mechanical shock, and stable mechanical performance in high and low temperature environments. They are suitable for high-reliability applications such as medical, military, industrial control, and automotive electronics.