Product family

Current Transformers

AC current transformers from 0.1 A board-level sensing to 5000 A busbar monitoring

Split-core CTs for live retrofits, class 0.2S–1 panel CTs with 1 A/5 A secondaries, PCB-mount nanocrystalline and permalloy CTs, ferrite CTs for 2–500 kHz switching currents, and three-phase assemblies. Choose the construction below, then narrow the table by input, output and mounting.

Split-core current transformer with cable output
current transformer models
191
rated primary current
0.1–5000 A
best accuracy class
0.2S
largest window
220×80 mm

Choose by construction

Each type solves a different installation problem. Pick the one that matches how the CT will be fitted, then compare models in its table.

Also in this family: DC-immune CTs (3) · composite core tolerates a DC component SMD CTs (2) · surface-mount nanocrystalline Multi-range CT (1) · selectable 10/30/50/70 A AC current switch (1) · self-powered, switches at 2 A AC

Go straight to matching models

Already know a key value? Each link opens the product table with that filter applied, and the number shows how many models match.

Core type

Can the conductor be opened? If not, only split-core will fit.

Rated input

The primary current range removes most models in one step.

Output signal

Match the meter or ADC input. Most models give a mA output; these find the rest.

Mounting

Board, panel, cable or DIN-rail mounting usually fixes the family.

CT, Rogowski coil or Hall sensor?

All four measure current without contact. Signal type, current range and installation decide which fits. Figures are the extremes of each PowerUC product family, not of one model.

This family Solid-core CT This family Split-core CT Rogowski coil + integrator Hall-effect sensor
MeasuresAC onlyAC only (DC-output models rectify an AC input)AC onlyAC and DC
Range in our catalogue0.1 A – 4000 A1 A – 5000 ACoils 30 A – 500 kA; integrators 100 A – 10 kA0.25 A – 5000 A
Stated accuracyClass 0.2S – 1 on 1 A/5 A types; precision types state linearity better than 0.2% or 0.1%0.2S – 5% by model0.5% – 1% (one integrator 2%)0.5–1% closed-loop; 1% open-loop and split-core
InstallationConductor threaded through the window, or PCB/busbar mount; the circuit must be openedClamps around a live conductorFlexible coil wraps a cable or busbar; integrator on DIN rail or plateThrough-hole or split-core housing
Power and saturationPassive; the magnetic core can saturate on overcurrent or a DC offsetPassive; the magnetic core can saturate on overcurrent or a DC offsetAir core does not saturate; output is di/dt, so an integrator is requiredActive: needs a 3.3–5 V or ±12–24 V supply
OutputmA, 0.1/1/5 A, 2.2 V or 3.53 VmA, 1 A/5 A, 0.333 V, 1–10 V AC or DCCoil mV/kA; integrator 0.333–10 V, 4–20 mA or 20 mA–5 A2.5 V ±0.625 V or ±2 V, ±4 V, or mA (closed-loop)

Ranges come from the rated input, accuracy and output data of the PowerUC current transformer, Rogowski coil and Hall sensor ranges. Rogowski coils vs current transformers, in detail

Where these CTs are used

Application notes that show which CT types and models each system design uses.

Variants and options

Many frames in this range already exist in several electrical and mechanical variants. Start from the closest listed model and tell us what has to change.

  1. Secondary current

    Distribution CTs are listed with 0.1 A, 1 A and 5 A secondaries, and other secondary currents can be specified.

  2. Output signal on one frame

    SCT024TS is listed with 20 mA–5 A, 0.333 V and 1/3/5 V outputs; -D versions add a rectified DC output.

  3. Core material in one footprint

    TA8348/8349/8350 come with nanocrystalline, permalloy, silicon-steel or DC-immune composite cores.

  4. Termination

    Leads, screw terminals, RJ11/RJ12 or a 3.5 mm plug; SCT013 offers RJ12 on request and SCT025B terminals or leads.

  5. Accuracy class

    BCT and BH distribution CTs are listed in classes 0.2S, 0.2, 0.5S, 0.5 and 1.

  6. Single- or three-phase

    Seven split-core sizes, Φ6 to Φ52 mm, also come as three-phase sets on one RJ12 connector.

What we need to quote

Send the operating conditions, not only a part number. The closest model from the table plus these values lets us confirm a standard part or a variant.

Include in your request

  • Rated and maximum primary current, and any overload or inrush
  • Frequency or waveform: 50/60 Hz, kHz switching, DC component
  • Conductor or busbar size, and whether the circuit can be opened
  • Output signal and burden: ratio, 1 A/5 A, 0.333 V or 0–5/10 V DC
  • Accuracy class or linearity, and phase-error limit for metering
  • Mounting and termination: PCB, panel, DIN rail, cable or busbar; pins, leads, terminals or RJ12
  • Insulation level, operating temperature and IP rating
  • Annual quantity and target date